交流采样器变送器仪表检验装置电话13708956461  1 概述

1 summarize

本装置是按照GB/T13729-92《远动终端通用技术条件》、DL/T630-1997《交流采样远动终端通用技术条件》和检定规程JJG126-95《交流电量变换为直流电量电工测量变送器检定规程》、国家电力公司《交流采样测量装置校验规范》、JJG124-2005《电流表、电压表、功率表和电阻表检定规程》、JJG 596-1999、JJG 307-2006的要求而设计的三相表源一体化装置。装置中表的核心技术用的是数字信号处理器(DSP)和16位高速模数转换器组成的高精度工频交流采集器;源的信号部分用的是DSP16位高速数模转换器组成可控制的正弦波、畸变波信号源。

This device is a three phase meter source integrated device contrived according to GB/T13729-92 remote terminal unit general technical specification, DL/T630-1997 alternating current sampling remote terminal unit general technical specification and vertification regulation JJG126-95 alternating current converting to direct current electrotechnical measurement transmitter vertification regulation, JJG124-2005 ampere meter, voltmeter, powermeter and resistance meter vertification regulation, and JJG 596-1999、JJG 307-2006. This device’s core technology is DSP and high precision power frequency alternating current collector constituted by 16 bit high-speed analog-digital converter, The source signal part is controllable sine wave, distortional wave signal source used DSP and 16 bit high-speed analog-digital converter.

装置具有精度高、工作稳定可靠;内置工控机,操作更加方便灵活等特点。

This device has the character of high precision, reliable, built-in Industrial Personal Computer, convenience.

2 主要功能及特点

2.1 可半自动或手动检验电力系统中各种工频电表(电压表、电流表、功率表、频率表、功率因数表、相位表)的基本误差,电压、电流、波形、功率因数等影响量引起的改变量等。

2.2 可自动检验电测量变送器(电压变送器、电流变送器、功率变送器、频率变送器、功率因数变送器、电能变送器)的基本误差,电压、电流、波形、功率因数等影响量引起的改变量等。

2.3 电源部分可生成具有2~31次谐波的畸变波,谐波个数、次数、幅度以及谐波对基波的相位均可程控。

2.4 功放的工作频带为40Hz~1kHz,有良好的线性。电流功放为恒流源,电压功放为恒压源。由于重量轻,本装置更适合于现场校验使用。

2.5 设有RS-232接口。通过上位机软件(选件),由计算机控制本装置可进行自动或手动检验,并对结果进行处理和管理。

2.6 装置内置工控机,支持仪表管理和测试数据的存储、浏览、打印、查询等功能。

2.7 可按电能表检测负荷点或自选点进行电能表校验。

2 The main function and characteristic.

2.1 This device can semi-automatically or manually detect all kinds of power frequency electricity meter(voltmeter, ampere meter, power meter, frequency meter, power factor meter, phase meter)’s intrinsic error and change caused by voltage, current, waveform, power factor.

2.2 This device can automatically detect electric measurement transmitter(voltage transmitter, current transmitter)’s fundamental error, variation caused by voltage, current, waveform, power factor.

2.3 Power section can generate distortional wave which has 2~31-harmonic wave. Harmonic wave number, time, amplitude and phase can all be controlled.

2.4 Power amplifier’s working band is 40Hz~1kHz, with great linearness. Current power amplifier is constant flow source, voltage power amplifier is constant voltage source. This device is fit for field calibration due to its light weight.

2.5 This device is equipped with RS-232 port. Optioned by upper computer software, controlled by computer to conduct automatic or manual test. It can also treat and manage results.

2.6 This device is equipped with built-in IPC, support instrument management and test data storage, browse, print and query.

2.7 This device can conduct electric energy meter verification according to electric energy meter detect load point or optional point.

3 主要技术指标

3.1  交流电压量程  50V、100V、200V、400V、600V     最大输出容量 20VA

3.2  交流电流量程  0.5A、1A、2.5A、5A、10A、20A   最大输出容量 20VA

3.3  交流电压、电流调节范围 0~130% FS, 调节细度 0.005% FS

3.4  工频交流电压、电流准确度       0.05% FS

3.5  有功功率(50V~400V准确度    0.05% FS

3.6  无功功率(50V~400V准确度    0.1% FS

3.7  电流对同名相电压的相位准确度  0.050

3.8  频 率  调节范围 45~65Hz,   调节细度 0.001Hz,调定值准确度 0.01Hz

3.9  相 位  调节范围0~359.990,  调节细度 0.010

3.10 交流电压、电流输出波形失真度    ≤0.3%

3.11 交流电压、电流及功率输出稳定度   ≤0.01% FS /60s

3.12 谐波2~31次,幅度0~40%,各次谐波相位细度0.010·N(N为谐波次数);

3.13 直流电压量程 75mV、75V、150V、300V、500V、1000V   最大输出容量20W

3.14 直流电流量程 0.5A、1A、2.5A、5A、10A、20A        最大输出容量20W

3.15 直流电压、电流调节范围0~120% FS(1000V量程0~105% FS),调节细度0.005% FS

3.16 直流电压、电流输出稳定度    ≤0.01% FS /60s(峰-峰值);

3.17 直流电压调定值准确度            0.05% FS

3.18 直流电流调定值准确度             0.1% FS

3.19 直流75mV输出(负载)准确度       0.1% FS

3.20 直流测量准确度(用于变送器输出测量)   0.02% FS(电压0±24V,电流0±24mA);

3.21 电能表测量(50V~400V综合误差        0.05级 (脉冲输出:三相额定值=6Hz

3.22 工作电源  单相220V±10%, 50Hz±5%

3.23 使用环境  温度200C±100C, 相对湿度≤85%RH

3.24 体积重量  约460×430×185mm3, 20kg(豪华型机箱24kg)。

 

冀ICP备10017211号-20